7.3.10. Auxiliary parameters


<< Prev   Next >>

/C <text string>

Passes a parameter to the application.

/ClearCache

Clear the cache of client/server calls, which stores form metadata, modules, module text search index, and more.

/AllowExecuteScheduledJobs -Off|-Force

Manage the execution of scheduled jobs. Start scheduled jobs on the client that was started first (excluding clients with AllowExecuteScheduledJobs –Off). Once the session of this client is closed, start scheduled job in any other active session. Once a session with AllowExecuteScheduledJobs –Force is started, new scheduled jobs are started in this session, regardless of the availability of other sessions.

/UC <access code>

Connect to the infobase with a connection lock enabled. If non-empty access code is set for lock you have to provide the access code in parameter /UC to bypass the lock.

/RunShortcut <file name>

Allows you to run the 1C:Enterprise with infobase list stored in the specified file. You can select a shared infobase list file (*.v8i), or an infobase shortcut file (*.v8l).

/AppAutoInstallLastVersion<mode>

Manages automatic installation of the new versions of the client application.

<mode> can take the following values:

  • +. Installation of the new versions is enabled.
  • . Installation of the new versions is disabled.

/Execute <external data processor file path>

Runs external processing with full path specified as the command value in the 1C:Enterprise mode immediately after the system start. When the /Execute parameter is specified the/URL parameter is ignored.

/URL <address>

Follow the link after opening the application. The links in e1c and http(s) format are supported:

  • If the link is external, search for a running client application by the connection string specified in the parameter. Note that a link cannot be opened if the client application has a modal or blocking window open. Then attempt to follow the local link that is a part of the original link, and activate the main application window. If the attempt is not successful, do not close the client application. If the original link does not include a local link (because it only includes the infobase address), activate the main client application window.
  • If a client application with the specified connection string is not found, use the connection string from the /URL option instead.
  • If the link is local, start the client application, then attempt to follow the local link.

For http(s) links, this option always starts or activates the thin client.